PRO process thermostats

The PRO cooling circulation thermostats are ideal for external applications where rapid temperature changes are required. The low filling volume permits rapid heating up in the connected application.

Features:
- Low-level and adjustable over-temperature protection with acoustic alarm for use with flammable and non-flammable liquids
- Command console can be detached and used as remote control
- LAUDA Varioflex pump (pressure/suction) with 8 selectable levels, connections rear
- SmartCool system for energy-saving digital cooling management including compressor on-off control
- SelfCheck Assistant for system diagnosis
- Retrofittable for upgrading with interface (RS 232/485, Profibus; EtherCAT; analogue or contact modules)
- USB and Ethernet interface equipped as standard
- All models are fitted with a pressure-suction pump
- PowerAdapt system for the use of the maximum possible amount of heat permitted by the power supply system
- RP models have hybrid cooling system (allow cooling using ambient air or, in addition, using cooling water)
- Power cord with angled plug (CEE7/7)

The units are available with two innovative removable control units, which can also be used as a remote control.

Base (E models):
- High-contrast OLED graphic display, clearly visible from a distance.
- Operation via cursor keys and function keys.
- Menu navigation with plain-text interface.
- One programme with up to 20 segments.

Command Touch (EC models):
- 5.7' touchscreen graphical user interface.
- Graphical display of the temperature profile.
- User management.
- Control unit capable of storing up to 100 programmes, each with up to 50 segments.
- Timer and weekly programmer, with up to 9 countdown timers.
- Data import and export via USB.

The PRO cooling circulation thermostats are ideal for external applications where rapid temperature changes are required. The low filling volume permits rapid heating up in the connected application.

Features:
- Low-level and adjustable over-temperature protection with acoustic alarm for use with flammable and non-flammable liquids
- Command console can be detached and used as remote control
- LAUDA Varioflex pump (pressure/suction) with 8 selectable levels, connections rear
- SmartCool system for energy-saving digital cooling management including compressor on-off control
- SelfCheck Assistant for system diagnosis
- Retrofittable for upgrading with interface (RS 232/485, Profibus; EtherCAT; analogue or contact modules)
- USB and Ethernet interface equipped as standard
- All models are fitted with a pressure-suction pump
- PowerAdapt system for the use of the maximum possible amount of heat permitted by the power supply system
- RP models have hybrid cooling system (allow cooling using ambient air or, in addition, using cooling water)
- Power cord with angled plug (CEE7/7)

The units are available with two innovative removable control units, which can also be used as a remote control.

Base (E models):
- High-contrast OLED graphic display, clearly visible from a distance.
- Operation via cursor keys and function keys.
- Menu navigation with plain-text interface.
- One programme with up to 20 segments.

Command Touch (EC models):
- 5.7' touchscreen graphical user interface.
- Graphical display of the temperature profile.
- User management.
- Control unit capable of storing up to 100 programmes, each with up to 50 segments.
- Timer and weekly programmer, with up to 9 countdown timers.
- Data import and export via USB.

Ver más
Features

* natural refrigerant

Model
P 2 E
Temperature range (ºC)
80 to 250
Temperature stability (ºC)
±0.05
Refrigeration
Water
Maximum heat output (kW)
2.5
Cooling capacity (kW)
-
Flow rate (l/min) - Pressure (bar)
22-0.68
Pump connection thread
M16x1
Min./max. fill volume (L)
2.4/4.4
Dimensions W x H x D (mm)
250x425x365
Pack (u.)
1
Reference
LAUL000019
Packaging
x u.
Price
Buy
Disponibility
Model
P 2 EC
Temperature range (ºC)
80 to 250
Temperature stability (ºC)
±0.05
Refrigeration
Water
Maximum heat output (kW)
2.5
Cooling capacity (kW)
-
Flow rate (l/min) - Pressure (bar)
22-0.68
Pump connection thread
M16x1
Min./max. fill volume (L)
2.4/4.4
Dimensions W x H x D (mm)
250x425x365
Pack (u.)
1
Reference
LAUL000020
Packaging
x u.
Price
Buy
Disponibility
Model
RP 240 E*
Temperature range (ºC)
-40 to 200
Temperature stability (ºC)
±0.05
Refrigeration
Hybrid
Maximum heat output (kW)
2.5
Cooling capacity (kW)
0.6 (20 ºC), 0.6 (10 ºC), 0.6 (0 ºC), 0.41 (-10 ºC), 0.24 (-20 ºC), 0.12 (-30 ºC), 0.02 (-40 ºC)
Flow rate (l/min) - Pressure (bar)
22-0.68
Pump connection thread
M16x1
Min./max. fill volume (L)
2.4/4.4
Dimensions W x H x D (mm)
300x675x430
Pack (u.)
1
Reference
LAUL000021
Packaging
x u.
Price
Buy
Disponibility
Model
RP 240 EC*
Temperature range (ºC)
-40 to 200
Temperature stability (ºC)
±0.05
Refrigeration
Hybrid
Maximum heat output (kW)
2.5
Cooling capacity (kW)
0.6 (20 ºC), 0.6 (10 ºC), 0.6 (0 ºC), 0.41 (-10 ºC), 0.24 (-20 ºC), 0.12 (-30 ºC), 0.02 (-40 ºC)
Flow rate (l/min) - Pressure (bar)
22-0.68
Pump connection thread
M16x1
Min./max. fill volume (L)
2.4/4.4
Dimensions W x H x D (mm)
300x675x430
Pack (u.)
1
Reference
LAUL000023
Packaging
x u.
Price
Buy
Disponibility
Model
RP 245 E*
Temperature range (ºC)
-45 to 200
Temperature stability (ºC)
±0.05
Refrigeration
Hybrid
Maximum heat output (kW)
2.5
Cooling capacity (kW)
0.8 (20 ºC), 0.8 (10 ºC), 0.8 (0 ºC), 0.53 (-10 ºC), 0.34 (-20 ºC), 0.15 (-30 ºC), 0.04 (-40 ºC)
Flow rate (l/min) - Pressure (bar)
22-0.68
Pump connection thread
M16x1
Min./max. fill volume (L)
2.4/4.4
Dimensions W x H x D (mm)
300x675x430
Pack (u.)
1
Reference
LAUL000022
Packaging
x u.
Price
Buy
Disponibility
Model
RP 245 EC*
Temperature range (ºC)
-45 to 200
Temperature stability (ºC)
±0.05
Refrigeration
Hybrid
Maximum heat output (kW)
2.5
Cooling capacity (kW)
0.8 (20 ºC), 0.8 (10 ºC), 0.8 (0 ºC), 0.53 (-10 ºC), 0.34 (-20 ºC), 0.15 (-30 ºC), 0.04 (-40 ºC)
Flow rate (l/min) - Pressure (bar)
22-0.68
Pump connection thread
M16x1
Min./max. fill volume (L)
2.4/4.4
Dimensions W x H x D (mm)
300x675x430
Pack (u.)
1
Reference
LAUL000024
Packaging
x u.
Price
Buy
Disponibility
Model
RP 250 E*
Temperature range (ºC)
-50 to 200
Temperature stability (ºC)
±0.05
Refrigeration
Hybrid
Maximum heat output (kW)
2.5
Cooling capacity (kW)
1.50 (20 ºC), 1.44 (10 ºC), 1.2 (0 ºC), 0.84 (-10 ºC), 0.54 (-20 ºC), 0.29 (-30 ºC), 0.11 (-40 ºC), 0.02 (-50 ºC)
Flow rate (l/min) - Pressure (bar)
22-0.68
Pump connection thread
M16x1
Min./max. fill volume (L)
2.4/4.4
Dimensions W x H x D (mm)
300x675x430
Pack (u.)
1
Reference
LAUL002494
Packaging
x u.
Price
Buy
Disponibility
Model
RP 250 EC*
Temperature range (ºC)
-50 to 200
Temperature stability (ºC)
±0.05
Refrigeration
Hybrid
Maximum heat output (kW)
2.5
Cooling capacity (kW)
1.50 (20 ºC), 1.44 (10 ºC), 1.2 (0 ºC), 0.84 (-10 ºC), 0.54 (-20 ºC), 0.29 (-30 ºC), 0.11 (-40 ºC), 0.02 (-50 ºC)
Flow rate (l/min) - Pressure (bar)
22-0.68
Pump connection thread
M16x1
Min./max. fill volume (L)
2.4/4.4
Dimensions W x H x D (mm)
300x675x430
Pack (u.)
1
Reference
LAUL002495
Packaging
x u.
Price
Buy
Disponibility
Model
RP 290 E*
Temperature range (ºC)
-90 to 200
Temperature stability (ºC)
±0.05
Refrigeration
Hybrid
Maximum heat output (kW)
2.5
Cooling capacity (kW)
0.80 (20 ºC), 0.77 (10 ºC), 0.74 (0 ºC), 0.72 (-10 ºC), 0.7 (-20 ºC), 0.68 (-30 ºC), 0.64 (-40 ºC), 0.56 (-50 ºC), 0.39 (-60 ºC), 0.21 (-70 ºC), 0.09 (-80 ºC), 0.01 (-90 ºC)
Flow rate (l/min) - Pressure (bar)
22-0.68
Pump connection thread
M16x1
Min./max. fill volume (L)
2.4/4.4
Dimensions W x H x D (mm)
390x685x600
Pack (u.)
1
Reference
LAUL002502
Packaging
x u.
Price
Buy
Disponibility
Model
RP 290 EC*
Temperature range (ºC)
-90 to 200
Temperature stability (ºC)
±0.05
Refrigeration
Hybrid
Maximum heat output (kW)
2.5
Cooling capacity (kW)
0.80 (20 ºC), 0.77 (10 ºC), 0.74 (0 ºC), 0.72 (-10 ºC), 0.7 (-20 ºC), 0.68 (-30 ºC), 0.64 (-40 ºC), 0.56 (-50 ºC), 0.39 (-60 ºC), 0.21 (-70 ºC), 0.09 (-80 ºC), 0.01 (-90 ºC)
Flow rate (l/min) - Pressure (bar)
22-0.68
Pump connection thread
M16x1
Min./max. fill volume (L)
2.4/4.4
Dimensions W x H x D (mm)
390x685x600
Pack (u.)
1
Reference
LAUL002503
Packaging
x u.
Price
Buy
Disponibility